Intek 111D Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Werkzeug Intek 111D herunter. Intek 111D User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 21
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
WARRANTY
Intek, Inc. warrants each Rheotherm product to be free from defects
in material and workmanship under normal use and service, Intek's
obligation under this warranty being limited to making good any part
or parts thereof which shall, within one (1) year after delivery of such
product to the original purchaser, be returned to Intek with
transportation charges prepaid and which Intek's examination shall
disclose to its satisfaction to have been thus defective; this warranty
being expressly in lieu of all other warranties, express or implied and
all other obligation or liabilities on Intek's part. The purchaser will
assume all responsibility and expense for removal, decontamination
and reinstallation of equipment.
Rheotherm flow meters are manufactured under United States patent numbers 4,255,968, 4,942,763, 4,949,578, 5,485,754 and 5,752,411
Intek, Rheotherm, Rheovec, and RheoVac are registered trademarks of Intek, Inc.
Intek, Inc.
751 Intek Way
Westerville, Ohio 43082-9057
TEL: (614) 895-0301 • FAX: (614) 895-0319
Seitenansicht 0
1 2 3 4 5 6 ... 20 21

Inhaltsverzeichnis

Seite 1 - Westerville, Ohio 43082-9057

WARRANTYIntek, Inc. warrants each Rheotherm product to be free from defectsin material and workmanship under normal use and service, Intek'soblig

Seite 2 - TABLE OF CONTENTS

- 8 -MAN114 REV C.wpdSECTION 3 ! OPERATION3.1 START UPTypically, the instruments come from the factory set up for the flow range of interest to the cu

Seite 3 - ! GENERAL INFORMATION

- 9 -MAN114 REV C.wpd3. Flow rate display — The standard display is a 3½ digit LED. The left digit shows only 0 or 1.4. Totalizer — The standard total

Seite 4

- 10 -MAN114 REV C.wpd3.4 OUTPUT CURVEFigure 3 (p. 20) is the final linearized output curve for your unit. The instrument has been calibrated overthe

Seite 5

- 11 -MAN114 REV C.wpd

Seite 6 - SECTION 2 ! INSTALLATION

- 12 -MAN114 REV C.wpdSECTION 4 ! MAINTENANCE4.1 GENERAL MAINTENANCECertain precautions should be taken to insure proper performance of all models of

Seite 7

- 13 -MAN114 REV C.wpd4.3 SPARE PARTSThere are no normally recommended spare parts to stock. The transducer and electronics are a matchedset and ther

Seite 8

- 14 -MAN114 REV C.wpdSECTION 5 ! CUSTOMER SERVICEIntek's corporate philosophy is to solve our customer's difficult flow measurement probl

Seite 9

- 15 -MAN114 REV C.wpdSECTION 6 ! CUSTOM INFORMATION6.1 UNIT IDENTIFICATIONModel no.: Serial no.: Customer identification: 6.2 CONFIGURATIONThe conf

Seite 10 - SECTION 3 ! OPERATION

- 16 -MAN114 REV C.wpdTABLE II. ORIGINAL CALIBRATION DATAFOR FUNCTIONAL TESTUnit Serial Number - I II III IV V VITEMP)T TP4Linea

Seite 11 - MAN114 REV C.wpd

- 17 -MAN114 REV C.wpdFigure 1

Seite 12

TABLE OF CONTENTSSECTION 1 ! GENERAL INFORMATION ... - 1 -1.1 INTRODUCTION ...

Seite 13

- 18 -MAN114 REV C.wpdFigure 2. Rheotherm® Signal Conditioner PWB Layout

Seite 14

- 19 -MAN114 REV C.wpdFigure 3. Flow Rate vs. Output CurveJUST A HOLDING SPACE

Seite 15

- 1 -SECTION 1 ! GENERAL INFORMATION1.1 INTRODUCTIONRheotherm® precision flow meters are designed to provide accurate linear or non-linear (depending

Seite 16

- 2 -MAN114 REV C.wpd1.2 DESCRIPTION OF OPERATIONRheotherm flow meters are available with various nonintrusive and intrusive transducer designs, butth

Seite 17 - Q None

- 3 -MAN114 REV C.wpd4. Check the transducer maximum temperature rating — do not operate a transducer at or subjectit to a temperature above its speci

Seite 18

- 4 -MAN114 REV C.wpdSECTION 2 ! INSTALLATION. IMPORTANT: All transducers have a directional arrow on the tagand/or etched into a metal part. Befor

Seite 19

- 5 -MAN114 REV C.wpdtube transducer, whether flanged or not, must not be used to pull other piping together or tomake up angular mismatch of fittings

Seite 20

- 6 -MAN114 REV C.wpdthe flow sporadic and difficult to measure. Control valves should be placed down stream ofthe sensor.The ideal installation will

Seite 21

- 7 -MAN114 REV C.wpd3. Laboratory — This table-top unit is NEMA 1 only; do not spill liquid on it or use in a wetenvironment. This unit typically ha

Kommentare zu diesen Handbüchern

Keine Kommentare