Intek 100FS Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Werkzeug Intek 100FS herunter. Intek 100FS User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
WARRANTY
Intek, Inc. warrants each Rheotherm product to be free from defects
in material and workmanship under normal use and service, Intek's
obligation under this warranty being limited to making good any part
or parts thereof which shall, within one (1) year after delivery of such
product to the original purchaser, be returned to Intek with
transportation charges prepaid and which Intek's examination shall
disclose to its satisfaction to have been thus defective; this warranty
being expressly in lieu of all other warranties, express or implied and
all other obligation or liabilities on Intek's part. The purchaser will
assume all responsibility and expense for removal, decontamination
and reinstallation of equipment.
Rheotherm flow meters are manufactured under United States patent numbers 4,255,968; 4,942,763; 4,949,578; 5,485;754 and 5,752,411
Intek, Rheotherm, Rheovec, Rheomax and RheoVac are registered trademarks of Intek, Inc.
Intek, Inc.
751 Intek Way
Westerville, Ohio 43082-9057
TEL: (614) 895-0301 FAX: (614) 895-0319
www.intekflow.com
Seitenansicht 0
1 2 3 4 5 6 ... 16 17

Inhaltsverzeichnis

Seite 1 - Westerville, Ohio 43082-9057

WARRANTYIntek, Inc. warrants each Rheotherm product to be free from defectsin material and workmanship under normal use and service, Intek'soblig

Seite 2 - TABLE OF CONTENTS

- 8 -3.3 ADJUSTING THE TRIP POINTAdjust the flow switch trip level as follows:1. Establish a flow rate at the desired trip level. (This should be don

Seite 3 - ! GENERAL INFORMATION

- 9 -2. The transducer isolation check is performed as follows (see Figure B):A. Disconnect the transducer cable from the electronics.B. Make the circ

Seite 4

- 10 -SECTION 4 ! MAINTENANCE4.1 GENERAL MAINTENANCECertain precautions should be taken to insure proper performance of all models of flow instruments

Seite 5

- 11 -4.3 TROUBLE SHOOTINGTABLE I. TROUBLE SHOOTING GUIDEOBSERVATION PROBABLE CAUSE REMEDYFlow trip level continuallydrifting downward with constantfl

Seite 6 - SECTION 2 ! INSTALLATION

- 12 -SECTION 5 ! CUSTOMER SERVICEIntek's corporate philosophy is to solve our customer's difficult flow measurement problems. Thismeans t

Seite 7

- 13 -SECTION 6 ! CUSTOM INFORMATION6.1 UNIT IDENTIFICATIONModel no.:Serial no.: Customer identification:6.2 CONFIGURATIONThe configuration of this u

Seite 8

~---i I ' i i ' ' i :;:=-0-_:;..!~· \ ~~,_-: ---~ -·----> L() I 0 L 0 <( E 0 C\J I ~ I FIGURE 1. Rheotherm 100 Rev. B Signal Con

Seite 10

TABLE OF CONTENTSSECTION 1 ! GENERAL INFORMATION ... - 1 -1.1 INTRODUCTION ...

Seite 11

- 1 -SECTION 1 ! GENERAL INFORMATION1.1 INTRODUCTIONRheotherm flow switches offer reliable flow switch protection in liquids, gases and slurries. The

Seite 12 - SECTION 4 ! MAINTENANCE

- 2 -Nonintrusive transducer(TU)Example of dual probewith flange fittingExample of single probewith NPT fitting1.2 DESCRIPTION OF OPERATIONRheotherm f

Seite 13

- 3 -5. Keep transducer wetted surfaces clean and free of permanent layer build-up.6. Do not exceed pressure limits of the tube or fittings.7. Maintai

Seite 14 - SECTION 5 ! CUSTOMER SERVICE

- 4 -SECTION 2 ! INSTALLATION2.1 TRANSDUCER. IMPORTANT: All transducers have a directional arrow on the tagand/or etched into a metal part. Before in

Seite 15 - ! CUSTOM INFORMATION

- 5 -Some TU transducers have an integrally mounted cable; do not pull on this cable, or attemptto remove the fitting where the cable enters the shell

Seite 16 - ~~\Y==~::I

- 6 -1. NEMA 4 The standard industrial housing, this enclosure is watertight (non-submersible)when the door is properly clamped shut. The housing

Seite 17

- 7 -SECTION 3 ! OPERATION3.1 START UPTypically, Rheotherm flow switches come from the factory set up for a 10 to 1 flow rate range, and withthe trip

Kommentare zu diesen Handbüchern

Keine Kommentare